RVS-DN 1000 VOLT SOFT STARTER |
|
|
 |
|
|
|
 |
| |
Brochure

|
Magnetek's RVS-DN 1000 is a fully featured,
digital soft starter designed for use
with AC Motors. The highly sophisticated
RVS-DN ensures smooth, stepless
acceleration and deceleration,
eliminating excess current and
mechanical shock on the motor and load.
The RVS-DN is highly reliable in even
the harshest of environments, reducing
down-time.
The heavy-duty design with shock and
vibration testing, corrosive environment
protection, and wide operating
temperature range make the RVS-DN
suitable for both under and aboveground
mining applications.
- Soft start and soft stop
- Pulse/kick start
- Current limit
–Reduced inrush current
–Reduced excess mechanical torque
during starting
- Dual start/stop characteristics
- Pump Control Software
- Slow Speed—jog (1/6 rated speed)
- Jog with electronic reversing
- Energy Saver
- Opto-isolated control inputs
- Local/Remote reset
- Torque and current control for
optimized starting and stopping
process
- Generator starting—Wide (45 to
65 Hz) auto tracking frequency range
- RS485 communication via Modbus,
Profibus or Modbus/TCP protocols
(option)
- Application-specific software
–2 starting ramps
–Master/slave configurator
- Heavy-duty design up to 65°C
operating temperature
- Corrosive environment protection
- Multi-language LCD display
- LED's for operational status
indication
- Multi-function programmable I/O
- Opto-isolated control inputs
- 3 change over output relays,
8A/250VAC
–"Immediate"—upon start
–"End of Acceleration"
–"Fault"—programmable to trip or
trip fail safe
- Analog output option card
–(0/4–20 mA, 0–10VDC)
- NEMA 1, 12, 4 (and more)
enclosures
- Bypass contactor
- Control voltage: 110–220VAC,
110VDC
- Fusing and/or circuit breaker
- Control power transformer
- Low voltage control devices
(selector switch, push buttons,
indication lights, etc.)
- Comprehensive motor protection
package
- Too many starts and start
inhibit
- Long start time (stall
protection)
- Electronic overload with
selectable curves
- Electronic shear-pin (jam)
- Undercurrent
- Phase loss
- Phase sequence and under/over
frequency
- Under voltage
- External fault
- Shorted SCR
- Wrong connection
- Over temperature
- Motor insulation test (option)
- Motor thermistor (option)
- Conveyors
- Mining cars
- Crushers and mixers
- Continuous miner
- Longwall shear
- Pumps
- Centrifuges
- Compressors
- Chillers
- Fans, blowers
- Starting from diesel generator
or weak main power supply
|
|
|